Production description:
Responsibility,bright future
The machine roomless passenger elevator is well versed the environmental protection concept, saves energy and reduces consumption, save the construction area increase the freeness of designers, thereby fully reflect the idea of environment friendly culture. Compared with the gearwheel elevator with the same load capacity, the machine roomless elevator can save 25% electricity and 10% of construction area. The company has broken the traditional rules that machine rooms must be set for elevator, and which providing limitless creation possibilities for the limited space of modern construction.
Main function
Standard function | ||||
1 | Inspection operation | 29 | Over speed protection | |
2 | Slow speed running | 30 | Contact protection for brake switches | |
3 | Automatic door opening time adjustment | 31 | Interphone communication | |
4 | Full load bypass | 32 | Wheeling protection | |
5 | Automatic turn off lighting and fun | 33 | Alarm bell | |
6 | Automatic return to home landing | 34 | Emergency lighting | |
7 | Door re-closing | 35 | Level switch protection | |
8 | Error recording | 36 | False call canceling | |
9 | Hoist way self learning | 37 | Automatic reversal call canceling | |
10 | Automatic door opening | 38 | Floor display directional setup | |
11 | Attendant service | 39 | Isolate running | |
12 | Bypass operation | 40 | Dot matrix floor indicator | |
13 | Automatic correction of floor position signal | 41 | Rolling display of running direction | |
14 | Lift locking | 42 | CAN communication protection | |
15 | Protection of door lock up outside dooor area | 43 | Arrival gong | |
16 | Infrared light curtain protection | 44 | Emergency return in case of fire | |
17 | Over load protection | 45 | Main control protection | |
18 | Reversal runing protection | 46 | Main control CPU WDT protection | |
19 | Anti-skip protection | 47 | Discretional setup of service floor | |
20 | Anti terminal switches protection | 48 | Test running | |
21 | Anti-terminal over running protection | 49 | Clock control | |
22 | Phrase protection | 50 | Direct landing | |
23 | Contactor protection | 51 | Load weighting device | |
24 | Failure analysis of shaft self learn | 52 | Full collective control | |
25 | Motor temperature protection | 53 | Door opening button (external) | |
26 | Door opening failure protection | 54 | Door opening button (internal) | |
27 | Protection for door lock short circuit | 55 | Fire running function | |
28 | Door lock failure for brake switches | |||
Optional function | ||||
1 | Open the door in advance | 10 | Remote control | |
2 | Direct parking | 11 | Camera function in the car | |
3 | Group control | 12 | Voice announcer | |
4 | Duplex control | 13 | Car assistant operation box | |
5 | On-duty peak service | 14 | Operation box for the handicapped | |
6 | Off-duty peak service | 15 | Intelligent calling service | |
7 | Door open time extending | 16 | IC card control function | |
8 | Car arrival gong | 17 | Leveling when power failure | |
9 | Remote monitor |
Our reference specifiction: | ||||||||
Machine roomless passenger elevator specifications | ||||||||
No. of persons | Rated capacity (kg) |
Rated speed (m/s) | Car net size | Door net size(DW*DH)mm | Shaft inside dimension | Max traveling height(m) | ||
W*D(mm) | 2P center opening | W*D(mm) | OH | Pit depth | ||||
6 | 450 | 1.0 | 1200*1000 | 700*2100 | 2100*1450 | 4500 | 1600 | 45 |
8 | 630 | 1.0 | 1400*1100 | 800*2100 | 2350*1620 | 4500 | 1600 | 45 |
1.6 | 4600 | 1700 | 60 | |||||
1.75 | ||||||||
10 | 800 | 1.0 | 1400*1350 | 800*2100 | 2350*1870 | 4500 | 1600 | 45 |
1.6 | 4600 | 1700 | 60 | |||||
1.75 | ||||||||
13 | 1000 | 1.0 | 1600*1500 | 900*2100 | 2550*2020 | 4500 | 1600 | 45 |
1.6 | 4600 | 1700 | 60 | |||||
1.75 |